Modern Power System Protective Relaying

التذاكر

Modern Power System Protective Relaying

Modern Power System Protective Relaying
27 - 31 أكتوبر 2024
Barcelona, إسبانيا
إسبانيا

What are the Goals?

By the end of this Modern Power System Protective Relaying training course, the participants will be able to:

  • Select fit-for-the-purpose protection relays and other related devices
  • Calculate fault levels and loadings of feeders and branches
  • Develop and analyze typical power systems and their associated protection systems
  • Analyze numerical relay protection for generators, transformers, motors, and transmission lines
  • Establish communication between protection devices and controllers

Who is this Training Course for?

This Modern Power System Protective Relaying training course is suitable for a wide range of professionals but will greatly benefit those who are involved in the operation, planning, design and maintenance of power systems. 

  • Project Engineers
  • Project Managers
  • Electrical Engineers
  • Electrical Technicians
  • System Operators
  • Design Engineers
  • Asset Engineers
  • Asset Managers
  • Planning Engineers
  • Planning Managers
  • Protection and Instrumentation Engineer
  • Commissioning Engineers and Technicians

Daily Agenda

Day One : Protective Devices and Earthing Systems

  • Protection zones and time-current characteristics curves
  • Per Unit System and modern software for protection
  • CT and VT types, specifications and applications
  • Fuse Types, applications, selection and coordination
  • Digital and numerical relay functionalities
  • Ungrounded vs. Grounded systems

Day Two : Feeder Overcurrent and Earth Fault Protection 

  • Merits and characteristics of feeder protection
  • IDMT O/C & E/F protection
  • Definite Time (DT) protection
  • High-set instantaneous protection
  • Transient overreach
  • Relay settings

Day Three : Transformer Digital and Differential Protection 

  • Transformer O/C and E/F Protection
  • Transformer unit protection (REF and Diff)
  • Buchholz and pressure relief operations
  • Transformer differential protection complexities & solutions
  • Unit and non-unit transformer protection
  • Digital transformer protection system

Day Four : Generator Protection, Directional Protection and Capability Curve 

  • Generator faults and protection features
  • Generator protection overview
  • Generator differential protection (Biased & Unbiased)
  • Generator overall protection
  • Generator full protection with numerical relays
  • Interpretation of generator capability curve

Day Five : Busbar Protection and Distance Protection for Overhead Lines 

  • Digital busbar protection schemes
  • Busbar High Impedance Protection
  • Frame leakage protection
  • Line distance protection
  • Line differential protection
  • Summary and question & answer

التذاكر

الوقت والتاريخ
الأحد، 27 أكتوبر 2024
البداية - 10:00 ص (Asia/Kuwait)
الخميس، 31 أكتوبر 2024
النهاية - 10:00 ص (Asia/Kuwait)

إضافة إلى التقويم

الموقع

Barcelona

Barcelona
إسبانيا
--Barcelona--

احصل على الاتجاه

منظِّم

Seattle International For Training

info@seattle-int.com
مشاركة

تعرف على آراء الجمهور عن هذه الفعالية، ثم انضم إلى المحادثة.